Aten PN0108 8-Port Power Over the NET™

Aten PN0108 8-Port Power Over the NET™ 
 
Výrobce
Servery, storage, racky
Kód
 146705
Part No.
 PN0108G-AX-GG

Altusen's PN0108 is equipped with eight hotpluggable ports for easy server room management. Each port can be individually controlled so that users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order. On/Off scheduling allows for preset start/shutdowns/restarts on a daily, weekly,monthly basis.The PN0108 is the most convenient, reliable and cost effective way to obtain access to your server room remotely.*


Remote power on / off / reboot control for eight outlets via TCP/IP and a built in RS-232 PON (Power Over the NET™) port
Local power on / off / reboot control via the PN0108's PON port to the computer's RS-232 port
Daisy chain up to 15 additional stations to control up to 128 outlets
Manual switching between Local and Remote access for each port via front panel push button switches
Individual control of each port - users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
Easy setup and operation via a GUI interface
Provides three configuration/management methods: Browser; Telnet; or Console Terminal
Safe shutdown and rebooting for Windows systems*
Overcurrent protection and recovery for each AC port (110 V model only); total port overcurrent protection (both models) - remote users can monitor the outlet status via the GUI interface
Separate circuits for the unit's power and the power to the devices - the power control status menu is still accessible even when an overcurrent condition trips the devices' circuit breaker
On/Off scheduling - allows everything from a one-time start/shutdown, to daily, weekly, etc. starts/shutdowns at user-specified times
Port grouping - perform the same action on a specified group of ports
LEDs for easy status monitoring
Two level (Administrator and User) security
Configuration can be reset
Firmware upgradeable - daisy chained stations receive the upgrade via the daisy chain bus
UL/TUV approved
Multiplatform support: Windows 2000/XP/Vista, Linux, Unix and FreeBSD.

*Safe shutdown and rebooting is supported if the Power Monitor utility has been installed
For more information about KVMs which can connect to PN0108, see Compatible KVM Table

*The PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features


Package Contents

1x 8-Port Power Over the NET™
1x AC Source Power Cord
8x Power Outlet Power Cords
8x Safe Shutdown Cables
1x PON Cable (DB9 F to DB9 M)
1x User Instructions
1x Mounting Kit :Rack mounting brackets and hardware
4x foot pads
1x Software CD

K výrobku je k dispozici pouze manuál v angličtině (nemá český manuál).

Dostupnost
Dostupnost na pobočkách
Hodnocení produktu
Hodnoceno 0x

    24 Měsíce Záruka

     
    Kontakt

    Nevíte si rady? Zavolejte mi.

    Produktová podpora

    572 433 860 (Po-Pá od 8 do 16)

    Popis produktu

    Altusen's PN0108 is equipped with eight hotpluggable ports for easy server room management. Each port can be individually controlled so that users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order. On/Off scheduling allows for preset start/shutdowns/restarts on a daily, weekly,monthly basis.The PN0108 is the most convenient, reliable and cost effective way to obtain access to your server room remotely.*


    Remote power on / off / reboot control for eight outlets via TCP/IP and a built in RS-232 PON (Power Over the NET™) port
    Local power on / off / reboot control via the PN0108's PON port to the computer's RS-232 port
    Daisy chain up to 15 additional stations to control up to 128 outlets
    Manual switching between Local and Remote access for each port via front panel push button switches
    Individual control of each port - users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
    Easy setup and operation via a GUI interface
    Provides three configuration/management methods: Browser; Telnet; or Console Terminal
    Safe shutdown and rebooting for Windows systems*
    Overcurrent protection and recovery for each AC port (110 V model only); total port overcurrent protection (both models) - remote users can monitor the outlet status via the GUI interface
    Separate circuits for the unit's power and the power to the devices - the power control status menu is still accessible even when an overcurrent condition trips the devices' circuit breaker
    On/Off scheduling - allows everything from a one-time start/shutdown, to daily, weekly, etc. starts/shutdowns at user-specified times
    Port grouping - perform the same action on a specified group of ports
    LEDs for easy status monitoring
    Two level (Administrator and User) security
    Configuration can be reset
    Firmware upgradeable - daisy chained stations receive the upgrade via the daisy chain bus
    UL/TUV approved
    Multiplatform support: Windows 2000/XP/Vista, Linux, Unix and FreeBSD.

    *Safe shutdown and rebooting is supported if the Power Monitor utility has been installed
    For more information about KVMs which can connect to PN0108, see Compatible KVM Table

    *The PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features


    Package Contents

    1x 8-Port Power Over the NET™
    1x AC Source Power Cord
    8x Power Outlet Power Cords
    8x Safe Shutdown Cables
    1x PON Cable (DB9 F to DB9 M)
    1x User Instructions
    1x Mounting Kit :Rack mounting brackets and hardware
    4x foot pads
    1x Software CD

    K výrobku je k dispozici pouze manuál v angličtině (nemá český manuál).


    Více informací
     

    Poslat info

    Dotaz k tomuto produktu

    Váš e-mail
    Dotaz

    Nalezli jste jinde na internetu nižší cenu?

    Váš e-mail
    Cena bez DPH
    Cena s DPH
    WWW
    Komentář
    Mám o tento produkt zájem

    Zaslat informaci o produktu známému

    Váš e-mail
    Zaslat na e-mail
    Komentář

    Nahlásit chybu

    Popis závady
    Váš e-mail

    Diskuse (0)

    Facebook Diskuse