ATEN PN-0108 8-Port Power Over the NET 10Amp
8-Port Power Over the NET™
PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features
Altusen's PN0108 is equipped with eight hotpluggable ports for easy server rooom management. Each port can be individually controlled so that users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order. On/Off scheduling allows for preset start/shutdowns/restarts on a daily, weekly,monthly basis.
The PN0108 is the most convenient, reliable and cost effective way to obtain access to your server room remotely
Features
Remote power on / off / reboot control for eight outlets via TCP/IP and a built in RS-232 PON (Power Over the NET™) port
Local power on / off / reboot control via the PN0108’s PON port to the computer’s RS-232 port
Daisy chain up to 15 additional stations to control up to 128 outlets
Manual switching between Local and Remote access for each port via front panel push button switches
Individual control of each port - users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
Easy setup and operation via a GUI interface
Provides three configuration/management methods: Browser; Telnet; or Console Terminal
Safe shutdown and rebooting for Windows systems*
Overcurrent protection and recovery for each AC port (110 V model only); total port overcurrent protection (both models) - remote users can monitor the outlet status via the GUI interface
Separate circuits for the unit’s power and the power to the devices – the power control status menu is still accessible even when an overcurrent condition trips the devices’ circuit breaker
On/Off scheduling - allows everything from a one-time start/shutdown, to daily, weekly, etc. starts/shutdowns at user-specified times
Port grouping - perform the same action on a specified group of ports
LEDs for easy status monitoring
Two level (Administrator and User) security
Configuration can be reset
Firmware upgradeable - daisy chained stations receive the upgrade via the daisy chain bus
UL/TUV approved
OS Support:Windows 2000, Windows XP, Windows Vista, LINUX, Unix and FreeBSD
*Safe shutdown and rebooting is supported if the Power Monitor utility has been installed
*The PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features
Package Content
1x PN0108 Station
1x AC Source Power Cord
8x Power Outlet Power Cords
8x Safe Shutdown Cables
1x PON Cable (DB9 F to DB9 M)
1x User Manual
1x Quick start guide
1x Mounting Kit :Rack mounting brackets and hardware
4x foot pads
1x Software CD
1x Registration card
do 2 dnů
Prodej
Cenu zjistíte po
přihlášení24 Měsíce Záruka
Poslat info
Dotaz k tomuto produktu
Nalezli jste jinde na internetu nižší cenu?
Zaslat informaci o produktu známému
Nahlásit chybu
Zařazení produktu
Diskuse (0)
Facebook Diskuse
Popis produktu
8-Port Power Over the NET™
PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features
Altusen's PN0108 is equipped with eight hotpluggable ports for easy server rooom management. Each port can be individually controlled so that users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order. On/Off scheduling allows for preset start/shutdowns/restarts on a daily, weekly,monthly basis.
The PN0108 is the most convenient, reliable and cost effective way to obtain access to your server room remotely
Features
Remote power on / off / reboot control for eight outlets via TCP/IP and a built in RS-232 PON (Power Over the NET™) port
Local power on / off / reboot control via the PN0108’s PON port to the computer’s RS-232 port
Daisy chain up to 15 additional stations to control up to 128 outlets
Manual switching between Local and Remote access for each port via front panel push button switches
Individual control of each port - users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
Easy setup and operation via a GUI interface
Provides three configuration/management methods: Browser; Telnet; or Console Terminal
Safe shutdown and rebooting for Windows systems*
Overcurrent protection and recovery for each AC port (110 V model only); total port overcurrent protection (both models) - remote users can monitor the outlet status via the GUI interface
Separate circuits for the unit’s power and the power to the devices – the power control status menu is still accessible even when an overcurrent condition trips the devices’ circuit breaker
On/Off scheduling - allows everything from a one-time start/shutdown, to daily, weekly, etc. starts/shutdowns at user-specified times
Port grouping - perform the same action on a specified group of ports
LEDs for easy status monitoring
Two level (Administrator and User) security
Configuration can be reset
Firmware upgradeable - daisy chained stations receive the upgrade via the daisy chain bus
UL/TUV approved
OS Support:Windows 2000, Windows XP, Windows Vista, LINUX, Unix and FreeBSD
*Safe shutdown and rebooting is supported if the Power Monitor utility has been installed
*The PN0108 is not a stand-alone unit. It must be connected to the CN6000, PN9108, SN0108 or SN0116 to access these features
Package Content
1x PN0108 Station
1x AC Source Power Cord
8x Power Outlet Power Cords
8x Safe Shutdown Cables
1x PON Cable (DB9 F to DB9 M)
1x User Manual
1x Quick start guide
1x Mounting Kit :Rack mounting brackets and hardware
4x foot pads
1x Software CD
1x Registration card